• Measures, displays and stores last test data, including discharge times, peak offset voltages, and average offset voltage.
• Easiest, most reliable way to check effectiveness of all ionization-type static control systems
• Meets Requirements of ANSI/ESD STM 3.1
• Removable, cable-connected ion collecting plate probe permits precise positioning and remote monitoring
• Separate time and voltage displays for discharge time test
модель : Monroe 300

The model 300 uses large, high-contrast, alpha/numeric LED displays for easy reading at any vieweing angle, even in high ambient lighting conditions. Individual LED’s, provide additional operation status during testing and setup. Single-button operation of manual +decay, -decay and balance ensures simple, easy operation. Balance tests record ±peaks and average reading. Each test can be customized in setup for stop trip levels and test duration. An automated set of tests can be initiated with a single button depress.

Operation and setup can be done via a USB port and PC software in addition to the front panel buttons. Test results can also be retreived for automatic or manual test.
Real time analysis of ionizers can be done via the analog output.

Charger:
±1100 volts, selectable polarity
Fieldmeter:

Range: 0 to ±1300 volts on display 

            0 to ±1800 volts analog output 

            1-volt resolution 

Accuracy: ±2% of reading ±2V + zero offset 

Bandwidth: 6Hz 

Analog output: 1/1000 of plate voltage, ±3% typical

Trip Points:

Start Voltage: 1000 volts fixed

 Stop Voltage: 10 to 990 volts in 1V steps

Charge Plate:

Size: 6”x6” (15cm x 15cm)

Capacitance: 20pf, ±10%

Plate self discharge: Less than 100 volts within 5 minutes (< 60% R.H.)

Timer:

Range: 0.1 sec to 999.9 sec

Resolution: 0.1 sec

Accuracy: 0.1 sec

Power Requirements:

100 to 220 VAC nominal line voltage; less than 5 Watts.

Battery Life:
>8 hours
Dimensions:
Approx 6.375”W x 8.5”D x 6H”
Weight:
Approx 5.2 lbs.





            

            

                    
  • Recorder output for permanent records and unattended operation
  • One range measures from 0 to ±1kV
  • Dramatically demonstrates induced charges and human body potential
  • AC and battery operation
  • Perform long-term balance tests